Stock Code: 300062
The Flexible Energy Storage Management Platform offers advanced control and monitoring for various battery types, ensuring optimal performance across residential, commercial, and utility-scale energy storage systems. With intelligent monitoring capabilities, it enhances energy efficiency, stabilizes power output, and provides scalable solutions to meet growing energy demands. This platform supports seamless integration with renewable energy sources, enabling smart energy distribution and cost-effective operations.
Model :
EPCP-EMS-5000iCapacity :
Refer to the Details PageApplications :
Intelligent Monitoring and MaintenanceProduct Origin :
ChinaSales Type :
Retail / Wholesale / Distributor SalesCustomization :
Support
01 |
Data Acquisition Collects information from BMS, PCS, protection, and auxiliary control devices. |
|
02 |
Data Processing Handles remote status, telemetry, calculation functions, and data quality code processing. |
|
03 |
Control Operations Manages remote control permissions, supervision, and operations. |
|
04 |
Alarm Functionality Provides real-time alerts, historical alarms, and incident recall capabilities. |
|
05 |
Communication Functionality Facilitates communication between the monitoring system, PCS, protection devices, and gateway with the dispatch master station. |
Control Indicators | |
Power Target Calculation Period | ≤20ms |
Response Delay for Power Command Execution | ≤30ms |
Power Regulation Response Time | ≤80ms |
Voltage Fluctuation Control Response Time | ≤80ms |
SOE Timestamp Accuracy | ≤2ms |
System Capacity |
|
Real-Time Data Capacity | ≥500K |
Historical Data Storage | ≥3Y |
Reliability |
|
Remote Control and Adjustment Accuracy | 100% |
System Availability | ≥99.99% |
Mean Time Between Failures (MTBF) | ≥40000h |
Operating Lifespan of Major System Equipment | ≥10Y |
Hardware Requirements |
|
CPU | At least 4-Core 1.6 GHz |
Memory | At least 16 GB RAM |
Hard Disk | At least 500 GB |
Graphics Resolution | At least 1024 x 768 Resolution |
Power Requirements |
|
Rated Voltage | AC 220V or AC 110V |
Permissible Deviation | ±15% to ±10% |
Ripple Factor | Not greater than 5% |
Frequency | 50Hz, with allowable deviation of ±5% |
UPS Power Supply | An uninterruptible power supply (UPS) or inverter power supply should be configured on-site, with the UPS maintaining normal system operation for 1 to 2 hours. |
Residential Storage Solutions
Utility-Scale Energy Storage Systems
Support for Various Battery Types
Intelligent Monitoring and Maintenance
Our hours
Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM