Stock Code: 300062
The XGN Series comprises two models: the XGN2-12 and XGN40-12, tailored for 10kV, 50Hz power systems. These modular metal-clad switchgears are engineered for efficient power reception, distribution, and protection, offering adaptability for diverse operational requirements. With robust designs and advanced technologies, they provide reliable performance in power plants, substations, industrial facilities, and urban grid systems. The XGN Series ensures high safety standards, easy installation, and minimal maintenance, making it an ideal choice for modern energy distribution networks.
Model :
XGN2-12 / XGN40-12Capacity :
Refer to the Details PageApplications :
Industrial Facilities / Commercial Buildings / SubstationsProduct Origin :
ChinaSales Type :
Retail / Wholesale / Distributor SalesCustomization :
NA
Rated Voltage | 3.6/7.2/12kV |
Rated Current | 630/1000/1250/2000/2500/3150A |
Rated Short-Circuit Breaking Current | 20/31.5/40kA |
Rated Short-Time Withstand Current (4s) | 20/31.5/40kA |
Rated Peak Withstand Current (4s) | 50/80/100kA |
Rated Short-Circuit Closing Current (Peak Value) | 50/80/100kA |
Ingress Protection Rating | IP2X |
Operating Mode | Electromagnetic, Spring-Charged |
Industrial Power Plants
Substations
Commercial Power Systems
Frequent Operation Environments
*Five Prevention refer to: Preventing Closing under Load, Preventing Opening under Load, Isolation Protection, Grounding Protection, Door Interlock Protection
Rated Voltage | 3.6/7.2/12kV | ||
Rated Current | 630/1000/1250kA | ||
Rated Frequency | 50Hz | ||
Rated Short-Time Withstand Current | 16/31.5/40kA | ||
Rated Peak Withstand Current | 40/80kA | ||
Rated Short-Circuit Duration Time | 4s | ||
Rated Breaking Current | 16/31.5/40kA | ||
Ingress Protection Rating | IP3X | ||
Rated Insulation Level | Main Circuit | Rated Power Frequency Withstand Voltage (1min) | 44.5kV |
Rated Lightning Impulse Withstand Voltage | 79.5kV | ||
Auxiliary Circuit | Rated Power Frequency Withstand Voltage (1min) | 2000V | |
Rated Voltage Of Auxiliary Circuit | AC220/110V;DC220/110V |
Industrial Facilities
Commercial Buildings
Substations
XGN2-12 | VS. | XGN40-12 |
Fixed metal-enclosed design | Design and Construction | Compact and lightweight construction, making it suitable for indoor use |
Flexible breaker options with ZN8A-10 vacuum circuit breakers | Breaker Options | Advanced VS1 or VSm vacuum circuit breakers for enhanced performance |
Provides a more traditional layout | Maintenance Accessibility | Higher breaker chamber for convenient maintenance |