Stock Code: 300062
The Low Voltage Withdrawable Switchgear, comprising the GCK and GCS series, is a flexible and reliable power distribution solution ideal for motor control, lighting systems, and power distribution in power plants, substations, and industrial facilities. Engineered for 50Hz systems, these switchgears accommodate a range of voltage ratings and current capacities, ensuring adaptability for diverse operational needs. Featuring a modular and withdrawable design, they provide ease of maintenance, operational safety, and long-term durability, making them indispensable for modern low-voltage applications.
Model :
GCS / GCKCapacity :
Refer to the Details PageApplications :
Power Plants / Substations / Industries Facilities / High-Rise BuildingsProduct Origin :
ChinaSales Type :
Retail / Wholesale / Distributor SalesCustomization :
NA
Rated Frequency | 50Hz | |
Rated Voltage | 380/660V | |
Rated Insulation Voltage | 660V | |
Rated Current | Horizontal Busbar | 630-3150A |
Vertical Busbar | 660A | |
Rated Short-Time Withstanding Current (A) | Horizontal Busbar | 80kA RMS/s |
Vertical Busbar | 50kA RMS/s | |
Rated Peak Withstanding Current (A) | Horizontal Busbar | 176kA |
Vertical Busbar | 105kA | |
Main Circuit Plug-in | 200/400A | |
Auxiliary Circuit Plug-in | 10A | |
Power Frequency Withstand Voltage(1min) | 2500V | |
Control Motor Maximum Capacity | 155kW | |
Ingress Protection Rating | IP20-IP40 | |
Operation Mode | Local, Remote, Automatic |
Rated Insulation Voltage | AC660(1000)V | ||
Rated Working Voltage | Main circuit | AC 380(660)V | |
Auxiliary Circuits | AC 380/220/110/24V DC 220/110V |
||
Rated Frequency | 50(60)Hz | ||
Rated Current of Horizontal Busbar | ≤4000A | ||
Rated Current of Vertical Busbar | 1250A | ||
Rated Peak Withstand Current(0.1s) | 105/176 kA | ||
Rated Short-Time Withstand Current(1s) | 50/80kA | ||
Enclosure Ingress Protection Rating | IP30/IP40 |
GCK | VS. | GCS |
Suited for general power distribution | Usage Scenarios | Designed for specialized applications like oil and chemical industries and high-rise buildings |
Supports up to 660V and 3150A | Technical Specifications | Handle up to 10kV, providing higher capacity for larger systems |
Thermal stability | Performance and Stability | Thermal stability and dynamic performance under varying loads |
Modular designs for easy configuration | Modularity and Customization | Advanced modularity for more complex setups |
High protection ratings | Protection Standards | Designed for higher levels of safety in harsher environments than GCK |